A Heatmap That Respects Walls
BMS floor plans colour each zone in one flat colour. We wanted a real thermal picture of the room, one that does not blend the cold aisle into the hot aisle through a rack.
On a BMS floor plan today, a “thermal map” means tiles. Each zone is a polygon, and the whole polygon is painted one colour from one sensor: green, amber or red. It tells you which room is warm. It does not tell you where in the room.
In a data hall that is not enough. Hundreds of sensors sit on rack inlets and exhausts, and the question is never “is this aisle warm?” but “which rack, and how far does it spread?”. Our Floor Plan Heatmap for Tridium Niagara answers that with a continuous field: exact at every sensor, smooth in between.

Why not just blend the sensors?
The obvious way past tiles is to blend: every point on the floor takes a weighted average of the sensors, nearer ones counting more. That works on an open floor. In a data hall it goes wrong at the first rack.
A rack inlet sensor reads 17 °C in the cold aisle. A metre away, behind the rack, an exhaust sensor reads 38 °C in the hot aisle. Measure “nearer” in a straight line and the blend paints a calm 27 °C right through the rack. That temperature does not exist anywhere in the room.
Distance the way air travels
The widget measures distance the way air would travel: around walls, not through them. For each sensor it works out how far every point on the floor is when you walk round the obstacles. The cold aisle stays cold, the hot aisle stays hot, and the boundary between them sits where the rack actually is.
On top of that:
- Zones with their own scales. A cold aisle at 16-22 °C and a hot aisle at 28-40 °C each get their own colour range, so neither washes out the other.
- Honest gaps. Far from any sensor, the colour fades out instead of inventing a value.
- Adjustable smoothness. Softer for broad trends, sharper to pick out a single hot spot.
Built to stay out of the way
It draws in the browser with WebGL. The JACE only serves the point values it already has, so there is no extra load and no extra server. Setup is a Niagara graphic with your floor plan, the widget on top, and one entry per sensor: bind it to a point, give it a position, done.
We also wrote the drawing code ourselves instead of pulling in a charting library. A Niagara module can run in a station for ten years without an update, and every outside dependency is something that can break in year six.
Not just data halls
Data halls were the first target, but anything measured by a network of sensors over a known layout fits. That includes cold stores, where you can see warm air at the dock doors, and pharma cleanrooms and stability rooms. It works just as well for office floors, CO2 included, and for greenhouses.